Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Vaccimonitor ; 24(1)2015.
Artigo em Espanhol | CUMED | ID: cum-63077

RESUMO

En los bancos de sangre de Cuba se cuantifica antitoxina tetánica, a partir del suero de donantes inmunizados, para producir una gammaglobulina humana específica. Se emplea un ensayo inmunoenzimático heterogéneo de tipo indirecto, que utiliza el suero como muestra analítica. En este trabajo se evalúo el posible empleo del plasma obtenido de la plasmaféresis como muestra alternativa, para minimizar el volumen de sangre total extraído a los donantes. Se seleccionó por muestreo aleatorio simple, 100 donantes de plasma que acudieron a donar entre octubre y noviembre del 2013. Para la obtención de suero se realizó una extracción de 5 mL de sangre por punción venosa, depositada en tubo de ensayo de cristal seco. La muestra de 1,5 mL de plasma se obtuvo al final de la donación, colectada en un tubo plástico con tapa. Se realizó la comparación de la diferencia de medias de ambos grupos, utilizando el programa estadístico informático SPSS para Windows. Los valores de antitoxina tetánica en suero fueron mayores que los del plasma. La media de las diferencias entre ambos grupos resultó estadísticamente significativa (p=0,00). No se recomienda usar el plasma que se obtiene de la plasmaféresis como muestra analítica para este ensayo(AU)


Tetanus antitoxin is quantified in Cuba at blood banks, from the serum of immunized donors, to produce a specific human gamma globulin. A heterogeneous indirect immunoenzymatic assay is used, using the serum as analytical sample. The possible use of plasma obtained from plasmapheresis as alternative sample was evaluated in this research, to minimize the volume of total blood extracted to the donors. One hundred plasma donors who came to donate between October and November 2013 were selected by simple random sampling. Serum sample was obtained for extraction of 5 mL of blood, deposited in dry glass tube. While the other sample took 1.5 mL of plasma in a plastic tube with cover, at the end of the donation directly of the unit of plasma collected. Comparison of the difference between the means of both groups was done using SPSS for Windows. It was found that the values obtained in serum were bigger than those obtained in plasma. Difference between the means of both groups was statistically significant (p 0.00). It is not advisable to use the obtained plasma of the plasmapheresis as analytic sample in this assay(AU)


Assuntos
Humanos , Cuba , Plasmaferese/métodos , Plasma/imunologia , Antitoxina Tetânica/uso terapêutico , Bancos de Sangue
2.
MEDISUR ; 6(1)2008. ilus
Artigo em Espanhol | CUMED | ID: cum-36798

RESUMO

Fundamento: La prevención de la transmisión de enfermedades infecciosas mediante la transfusión de sangre presenta uno de los desafíos más grandes para la medicina transfusional. Objetivo: Diseñar un sistema computarizado para el control de los donantes de sangre con resultados positivos a exámenes seroepidemiológicos. Métodos: Sistema diseñado en el banco Provincial de Sangre de Cienfuegos, con Microsoft Access como gestor de bases de datos y DELFHI 7 como lenguaje asociado; corre sobre el sistema operativo Windows 2000 o uno superior con 64 MB de RAM y no precisa de requerimientos especiales de hardware o software. Incluye lo siguientes datos: nombre y apellidos, edad, sexo, color de la piel, número de carné de identidad, dirección de residencia, número de historia clínica en el banco y la fecha en que ha sido realizado el ensayo (de cada paciente), tipo de enfermedad que ha sido diagnosticada, datos técnicos del ensayo tales como: fluorescencia y nivel de corte tanto del primer ensayo como la repetición, nombre del técnico que lo realizó. Resultados: Permite consultar datos generales de los donantes, así como enfermedad diagnosticada, posibilita elaborar reportes de estos pacientes desde cualquier computadora del banco de sangre que acceda a la base de datos al contar con la clave de seguridad del programa. Garantiza agilidad y uniformidad en la información. Conclusiones: Constituye una herramienta que permite perfeccionar el sistema de notificación establecido en la red del programa de Infecciones de Transmisión Sexual del MINSAP(AU)


Background: Prevention of infectious diseases transmission through blood transfusion is one of the biggest challenges in the transfusion field of medicine. Objective: to design a computerized system for blood donors control with seropositive results in epidemiological tests. Methods: A system designed by the Provincial Blood Bank using Microsoft Access as a data base system and DELFHI 7 as associated language. It runs under Windows 2000 or any other superior system with 64 RAM and do not need special requirements of software or hardware. It includes the following data: Full name, age, sex, race, Id number, home address, number of the clinical record in the blood bank, date when the trial took place in each patient, kind of disease diagnosed, technical data of the trial such as: fluorescence, sectional level of the 1st trial as well as the repetition, name of the technician who performed it. Results: It permits to consult general data of donors as well as the disease diagnosed. It also permits to elaborate reports of these patients from any PC of the blood bank acceding with the security password of the program. Conclusions: It constitutes a beneficial tool which permits to improve the notification system established in the program of the web about sexually transmitted diseases from the Minister of Public Health in Cuba


Assuntos
Humanos , Sistemas Computadorizados de Registros Médicos , Doadores de Sangue , Bancos de Sangue/normas , Bases de Dados como Assunto , Testes Obrigatórios , Controle de Infecções
3.
Medisur ; 5(1,n.esp)2007. graf, tab
Artigo em Espanhol | CUMED | ID: cum-39541

RESUMO

Fundamento: La evaluación y ayuda pronóstica aportada por los sistemas mensurativos internacionalmente reconocidos en la atención a enfermos con neuroictus presenta aciertos y desaciertos. La emisión de un pronóstico que estratifique la discapacidad es, al parecer, improcedente con tales instrumentos. Creado en el país un sistema que compila las citadas escalas de medición se hace viable efectuar una investigación que defina los postulados anteriores. Objetivo: Determinar las ventajas y desventajas de los sistemas mensurativos internacionales establecidos para el pronòstico de enfermedades cerebrovascualres. Métodos: Se implementó el sistema de instrumentos internacionales, compilados en un mismo sistema, con una serie de 202 casos en un período de 5 meses. Se efectuó una caracterización de la serie y se aplicaron test para determinar los coeficientes de correlación y resultados estadísticamente significativos al correlacionar los instrumentos utilizados con el estado al egreso según escala de Rankin. Resultados: Se constató un predominio del neuroictus isquémico de tipo aterotrombótico en edades avanzadas de la vida, se patentizó la discapacidad generada por el neuroictus. Se demostró el valor en la evaluación y la inferencia pronóstica de algunos instrumentos internacionales, pero se evidenció que no pronostican discapacidad de forma subestratificada. Conclusiones: Los instrumentos internacionales de medición en el neuroictus no son efectivos para la evaluación y seguimiento del paciente, la ayuda aportada por estos en la emisión pronóstica es inferida y con limitaciones, por lo que sería loable crear un sistema mensurativo único más simple y predictor(AU)


Background: Assessment and prognosis aid brought on by the mensurable international systems recongized in the attention of patients suffering from neuroictus has its success and mistakes. The emission of a prognosis which establishes a strategy for discapacity seems to be not to proceed with such instruments. In our country was created a system that compiles the above mentioned ratings which make viable to do a research which define the above postulates. Objective: To determine the advantages and disadvantages of the mensurable international systems. Methods: The international instrument system was implemented compiled in one system with 202 cases in a five-month period of time. A characterization of the serie was carried out and tests were applied to determine the correlation coefficient as well as significant statistics results when correlating the instruments wth the state of the patient at the moment of discharging according to Rankin scale. Results: A predominium of ischemic neuroictus of atherothrombosis type was verified in elderly. The discapacity generated by neuroictus was evident. The value in the assessment and the prognosis inference of some international instruments was shown. But there was evidence that they do not give the prognosis of the disability in a sub stratified way. Conclusions: The international measuring instruments in the nueroictus are not effective for the assessment and follow up of the patient. The contributed aid of these instruments in the prognosis emission is inferred and has limitations, so it will be commendable to create a more simple and unique predictable mensurable system(AU)


Assuntos
Humanos , Pesos e Medidas , Acidente Vascular Cerebral/diagnóstico , Prognóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...